The Leica DISTO D5 is particularly suitable for distance measurements in outdoor areas. Due to the digital Pointfinder, aiming is no problem even in sunshine and at very long distances. Both the target and the measurement results can be seen very clearly on the large display with IPS technology. For maximum accuracy, the measurement can be triggered by gestures, which is a distinct advantage, especially over long distances. High flexibility is offered by various functions, such as Smart Horizontal Mode, height tracking, profile or angle measurements. This means that any measurement situation on the construction site can be solved quickly and efficiently. The data can then be transferred to the DISTO Plan app or individual templates, e.g. in Excel, and processed further to support an efficient and error-free digital workflow.
| Leica DISTO D5 |
Accuracy with favourable conditions * | 1.0 mm / 1/16" *** |
Accuracy with unfavourable conditions ** | 2.0 mm / 1/8" *** |
Range with favourable conditions * | 0.05 – 200 m / 0.07 – 660 ft *** |
Range with unfavourable conditions ** | 0.05 – 120 m / 0.07 – 400 ft *** |
Smallest unit displayed | 0.1 mm / 1/32 in |
X-Range Power Technology | yes |
Laser Class 2 | 635 nm, <1 mW |
Digital Pointfinder with 4-fold zoom | yes |
Tilt measuring range **** | 360° |
Tilt measuring tolerance | ± 0.2° |
ø laser point | at distances | 6 / 30 / 60 mm | 10 / 50 / 100 m |
Protection class | IP54 (dust- and splash water protected) |
Auto. laser switch off after | 90 s |
Auto. power switch off after | 180 s |
Bluetooth® Smart | Bluetooth® v5.0 |
Range of Bluetooth® | up to 10 m |
Battery durability (Li-Ion 2 000 mAh) | up to 5’000 measurements up to 10 hours operation time |
Dimension (H x D x W) | 144 x 60 x 24 mm | 5.7 x 2.4 x 0.9 in |
Weight (with batteries) | 180 g / 6.35 oz |
Temperature range storage | operation | -25 to 70 °C / -13 to 158 °F | -10 to 50 °C / 14 to 122 °F |
* favourable conditions: white and diffuse reflecting target (white painted wall), low background illumination and moderate temperatures.
** unfavourable conditions: targets with lower or higher reflectivity or high background illumination or temperatures at the upper or lower end of the specified temperature range.
*** Tolerances apply from 0.05 m to 10 m with a confidence level of 95%. Above 5 m the tolerance may deteriorate according to the values given in the manual of the unit.
**** after user calibration. Additional angle related deviation are according to the values given in the manual of the unit.